सोलर खेती

Solar Plant Ki Generation Kam Kyu? Top 7 Karan aur Solution

Dhool, shade, inverter fault, tilt galat, curtailment, purane panel, monitoring nahi — generation badhane ke 7 practical tips.

लेखक: Ask Kisan Editorial4 min readRead in English
Kam output wala solar plant check

Pehle saal solar pump ya chhat wala plant achha unit de raha tha. Ab lagta hai 30–40% kam — bill utna nahi gira, ya pump solar par kam chalti hai. Panel "kharab" bolne se pehle ye 7 reasons check karo. Zyada fix saste hain; ignore karoge to poore life mein lakhon ka nuksan.

Ye checklist PM-KUSUM pump, khet ki chhat, aur chhote plant sab par lagti hai. Dhool detail ke liye dhool cleaning guide dekho.

Ek raat mein achanak generation giri? Pehle inverter fault code — panel "mar gaye" assume mat karo.

Reason 1 — Dhool (soiling)

Rajasthan, Gujarat, UP, Haryana mein katai aur hawa ke baad dhool ki parat — bird droppings bhi.

HalatLoss
Halki dhool5–10%
4 hafte barish nahi15–25%
Tractor ke paas mitti20–35%

Fix: Subah thande panel par paani + soft brush. Dry season mein mahine mein ek baar; kachchi sadak ke paas weekly. Dhool guide aur barish-dhool tips.

Reason 2 — Shade (ped / building)

Ek shaded cell poori string ko kheench sakta hai.

Farm par common:

  • Neem / eucalyptus badh gaya
  • Naya tanki, murgi farm, bhus ka dher
  • Agrivoltaics ka shadow purane panel par
  • Bijli ka khambha subah/shaam

Fix: Ped trim (jahan allowed); obstacle hatao; permanent shade ho to re-string vendor se. 9 baje, 12 baje, 3 baje site dekho.

Reason 3 — Inverter fault / galat setting

Grid issue, garmi, ya export limit se inverter limit mode mein.

Check karo:

  • Fault code photo
  • DISCOM ne export cap lagaya? (jaise 70%)
  • Fan par makdi ka jala — overheat
  • App offline — problem tab pata jab bill aaye

Fix: Vent saaf, grid stable par reset, authorised service. Grid pump: inverter trip fix.

Reason 4 — Galat tilt / direction

India mein panel south face + tilt (~latitude angle). Flat chhat par 10–15% saal bhar loss.

GaltiAsar
0° flatSardi mein kam
Galat directionSubah ya dopahar weak

Fix: Naya install — vendor simulation. Purana — bracket ho to season mein tilt adjust; warna accept ya next service par re-mount.

Reason 5 — Curtailment (grid export band)

Grid full ho to DISCOM curtailment — inverter export kam ya band. Rajasthan aur high-solar state mein dopahar shutdown ki shikayat common.

Signs: App par 11–2 baje zero export; same feeder par aur log bol rahe hain.

Fix: Panel issue nahi — DISCOM complaint + log. Detail: Rajasthan curtailment. Battery/hybrid pehle cost dekho.

Reason 6 — Ageing (purane panel)

Achhe panel 0.5–0.8% / saal lose karte hain. 8–10 saal baad 5–8% kam normal — 40% nahi.

Shak ho to: brown cell (hot spot), pani andar, ek string bahut kam monitoring mein.

Fix: Vendor thermal scan; warranty claim; sirf kharab module badlo, poora plant nahi.

Reason 7 — Monitoring nahi (pata hi nahi chalta)

Install ke baad app kabhi khola nahi — jab tak bill na aaye.

Minimum habit:

  • Roz ya hafte mein kWh note
  • Pichhle saal same month se compare
  • Toofan / katai ke next day check
  • Inverter ke paas vendor number chipkao

App nahi to meter reading hafte mein manual.

Quick table — symptom se reason

SymptomReasonPehla step
Dheere-dheere kamDhoolPanel saaf
Barish ke baad phir kamDhool wapasDhulai + neeche paani check
Ek string kamShade / loose wireDekho + electrician
Dopahar zero, sun strongCurtailmentDISCOM ticket
Saal 1 se hi sab kamTilt / designVendor review
8+ saal slow kamAgeingPerformance test

Season calendar (short)

MahinaKaam
March–AprilSummer se pehle saaf; earthing
May–JuneDaily monitor; fan saaf
July–AugustToofan ke baad check
Oct–NovKatai ke baad dhool
DecemberSaal bhar kWh compare

Generation kam par bill zyada? Saving kyu nahi — raat ko grid par pump chal raha ho sakta hai jab tum sirf din ka kWh dekhte ho.


Disclaimer: Har khet par alag. State DISCOM rule badalte hain. Technical kaam empanelled vendor se karwao. Ask Kisan EPC company nahi hai.

Last verified: June 2026.

खर्च, सब्सिडी और योजना के नियम राज्य और फंडिंग विंडो के हिसाब से बदलते रहते हैं। निवेश से पहले हमेशा आधिकारिक पोर्टल (nhb.gov.in, mnre.gov.in, agriinfra.dac.gov.in और अपने राज्य के बागवानी पोर्टल) पर जांच करें।

अक्सर पूछे जाने वाले प्रश्न

Solar pump ya plant ki generation kam kyu ho rahi hai?

Top 7 reasons: panel par dhool, naya shade (ped/building), inverter fault ya galat mode, galat tilt/direction, grid curtailment, panel ageing, aur monitoring nahi karne se problem late pata chalti hai.

Dhule panel se kitna loss hota hai?

Rajasthan, Gujarat jaisi jagah 10–25% tak loss barish ke beech common hai. Katai ke baad 15–30% tak girti hai jab tak saaf na karo. Safe cleaning ke liye alag guide padho.

Kya DISCOM meri generation rok sakta hai?

Haan — curtailment tab hota hai jab grid export absorb nahi kar paati. Rajasthan jaisi jagah dopahar ko strong sun ke bhi export band ho sakta hai. Ye panel kharab nahi, grid issue hai.

Kya 5–10 saal baad panel kam dete hain?

Haan, slow degradation — saal mein lagbhag 0.5–0.8%. 10 saal baad 5–8% kam normal hai. Achanak 30–40% drop usually dhool, shade ya inverter hota hai.

Roz generation kaise track karein?

Inverter app ya vendor ka portal — daily kWh note karo, pichhle saal ke same month se compare karo. PM-KUSUM install par login maangna mat bhoolna.